PRODUCTS CENTER

50 psi oxygen hose uk

Torch difference? oxy/ace. and other stuff - mig-welding.uk

18/11/2007· • You should not run an oxygen tank below 50 PSI. Acetylene Cylinders • Usually black, large in diameter and short • 250 PSI when full • The cylinder valve should only be opened ¼ of a turn. • The acetylene cylinder should never be laid down as this will result in the gas becoming unstable. • You should not run an acetylene tank below 50 PSI. HOSES: The oxy acetylene welding hoses

Western 1/8" NPT 50 psi Medical Oxygen Ohmeda

Qty. Package Size: 1 Each. 79.34. $79.34 Each. $79.34 Each. EA. WESMQ201-4 Western 1/8" NPT 50 psi Medical Oxygen Ohmeda® Quick Connect. Typically in Stock. Add to cart.

High Pressure Hoses | Manufacturer

Ultra High Pressure Waterblast Hose - 55,000 psi - 2849D. Parker 2849D Hoses are developed for ultra high pressure water jet cutting equipment with water or with abrasive additives. 1 Part Viewing 10 of 1 Show More . Close. Black Eagle Hose with ColorGard™ Oilfield service hose. Also used as fracing hose alternative to iron pipe (up to 70% lighter). Handles pressures up to 15,000 psi. 7

INDUSTRIAL HOSE & FITTINGS - ALFAGOMMA

through the hose wall . HOSE DUCTING & VENTILATION GAS & WELDING COMPRESSED AIR HOT AIR WATER & LIQUIDS AGRICULTURE FIRE FIGHTING FURNACE & CABLE COOLING HOT WATER & STEAM LIQUID FOOD BULK FOOD BULK MATERIAL SANDBLAST PLASTER CONCRETE ACID, CHEMICAL & MULTIPURPOSE HYDROCARBONS MARINE DOCK FLOATING ROOF DRAIN RIG …

Oxygen DISS Fittings - Medical Testing Solutions - Order

Superior MA – 740, DISS – 1240 – A Body – Adaptor for Oxygen. $ 3.92. Read More. Add to Wishlist. Product added! Browse Wishlist. The product is already in the wishlist! Browse Wishlist. Superior MC – 124, DISS – 1240 – A Hose Coupler for Oxygen.

Oxy-Acetylene Quiz Flashcards | Quizlet

The oxygen regulator has a 100 psi bursting disk on the back of the regulator. True . What is done to an oxygen tank to show that is has passed hydrostatic inspection every 10 years? Stamped. What safety device is used on an oxygen cylinder? Bursting disk. What causes the bursting disk on an oxygen tank to go off? Pressure. If you are going to use a large heating tip you will use a large

Best Oxygen Tank Regulator with Flow Meter | Medical

9/2/2021· Responsive Respiratory E Series Value Oxygen Regulator with the flow meter- 15 LPM is intended for the administration of oxygen to patients who need to increase oxygen levels to improve their breathing conditions. In addition, some models may be used in emergency situations. In an emergency situation, one should be sure to contact a physician or EMS immediately. It is a 15 LPM …

OzoneLab™ Oxygen Flow Regulators

High pressure cylinder oxygen is regulated to 50 psi (345 kPa) before passing through the flow control valve and barbed outlet fitting. To ensure safe operation, each regulator is equipped with an internal safety relief valve. Oxygen tanks with the oxygen flow regulator with North America standard oxygen CGA540 cylinder valve connections are supplied with the majority of GE and OL ozonation

Oxygen and other Compressed Medical Gas Rules and

Central Oxygen Supply: a system that consists of a remote oxygen source and supply tubing that is piped to other areas. Same as for all medical gas. H Cylinder: Large tank used as a central oxygen source and holds 6,910 liters. E Cylinder: Small tank usually attached to the anesthesia machine via a pin index yoke and holds 655 liters. Manifold: A device for connection oxygen or any medical gas

MEDICAL O2 REGULATOR CGA 540 50 PSI WITH 0-15 LPM FLOW

MEDICAL O2 REGULATOR CGA 540 50 PSI WITH 0-15 LPM FLOW GAUGE, M1-540-FG. $ 158.99. FEATURES: Medical Diaphragm O2 Regulator CGA 540 Inlet Connection DISS 1240 (02) Outlet Connection 50 PSI 0 – 15 LPM Flow Gauge 6 – year warranty.

Airgas - WESWMH-2-13 - Western 12'' CGA-440 Oxygen 50 psi

Qty. Package Size: 1 Each. 773.38. $773.38 Each. $773.38 Each. EA. WESWMH-2-13 Western 12'' CGA-440 Oxygen 50 psi 316 Stainless Steel Cryogenic Transfer Hose. Typically in Stock. Add to cart.

Anaesthesia UK : Introduction to medical gases

9/6/2005· The hose to the anaesthetic machine should be at a regulated pressure of 50 psi (i.e the regulator should be attached to the cylinder and not to the anaesthetic machine). E - attached directly to the anaesthesia machine via a yoke. Size: Capacity (litres) Oxygen: Nitrous oxide. E: 680: 1800. J: 6800: 18000. Gases found on anaesthesia machines Oxygen - stored as a gas at 13,700 kPa Nitrous

Welding Regulators - Grainger, Canada

Compare. UNIWELD. REGULATOR SNGLE STGE OXY CGA540. Item # UNWRV8010. Mfr. Model # RV8010. RV 80 heavy-duty single stage regulator. Forged brass body and bonnet. Easy-to-read single scale 2-1/2 in gauges. 3-1/4 in stainless steel diaphragm. Delrin bushing for smooth flow adjustment.

Smith Little Torch - Setup and Advice. – Pepetools

13/12/2020· But basically the pressure in PSI equates to the nuer of the nozzle. For a nuer 3 nozzle set the fuel and Oxygen regulators to 3 PSI, for a nuer 6 nozzle set them to 6 PSI and so on - simple ! The multi-jet casting nozzles require 10 PSI Fuel and 14 PSI Oxygen. See separate information on the optional natural gas casting nozzle.

Oxy-fuel welding and cutting - Wikipedia

In the UK and other countries, the oxygen hose is blue (black hoses may still be found on old equipment), and the acetylene MAPP gas can be used at much higher pressures than acetylene, sometimes up to 40 or 50 psi in high-volume oxy-fuel cutting torches which can cut up to 12-inch-thick (300 mm) steel. Other welding gases that develop comparable temperatures need special procedures …

Introduction to Oxy-Acetylene Welding

Oxygen Hose (green) Acetylene Hose (red) 1 3 5. 9 Barrel. Torch Head REGULATOR SETTINGS. 14 | The School of the Art Institute of Chicago 15. Install tip into mixer, hand tighten nut on top with touch tip facing to the left (for right hand use) or facing right (for left-hand use). Check torch handle. to make sure it is closed by gently turning knobs counter clockwise to open and then clockwise

Manifolds - Mercury Medical

50 psi Flow Settings: 0-15 lpm variable ORDERING INFORMATION Part# Description #EC-PM106 Oxygen Supply Manifold, one 20 ft Oxygen Hose, 6 Oxygen Therapy Masks and Carrying case #EC-505137-50 Oxygen Therapy Mask (case of 50) #EC-505136 20 ft Oxygen Supply Hose, DISS x DISS V- Vortran A- Automatic R- Resuscitator Oxygen Supply Manifold Oxygen Therapy …

ISO3821 En559 Rubber Welding 300 Psi Gas Oxygen Acetylene Hose

Product Description. ISO3821 EN559 Rubber Welding 300 PSI Gas Oxygen Acetylene Hose. Appliion. Extruded hose used for welding, cutting and allied processes. Temperature. -20ºC (-4ºF)to +70ºC (+158ºF) Tube. Black, smooth, synthetic rubber.

Pressure Loss Calculator | Pacific Hoseflex

Download Pressure Loss graph (PSI per foot of Hose) > Keep in mind that if you transfer gaseous substance through the hose then you need to find the ratio of the density of gas over the density of water and adjust the pressure drop respectively. For example if you transfer natural gas (density = 0.050 lb/ft 3) and knowing that water density = 62.4 lb/ft 3 we can find out the pressure drop as

Hydraulic Hose, Industrial Hose, Metal Hose, erhose

Call on 0333 6000 501 - The UK''s Original online Hose Store. Hydraulic Hose & Fittings, Industrial Hose & Fittings, Metal Hoses, Braided Hoses, Gas Hoses, Solarhoses, Pluing Hoses, Building Services Hoses, WRAS Hoses, plus a massive range of other fluid power components.

Regulators/Adjustable/Oxygen - Mercury Medical

• Maximum inlet pressure 3000 psi • Durable neoprene diaphragm • Internal reseating relief valve protects against over pressurization • UL Listed • 2” diameter gauges on M1 Series • 1-1/2” diameter gauges on MR Series Compact • Sintered filter for additional safety and to extend regulator life • Standard D.I.S.S. 1240 outlet connection and plastic swivel hose barb • 6

Drive Medical CGA 870 Mini Oxygen Regulator 0 - ebay.uk

Share - Drive Medical CGA 870 Mini Oxygen Regulator 0-15 LPM Barb Outlet Model 18302GMN. CURRENTLY SOLD OUT. Drive Medical CGA 870 Mini Oxygen Regulator 0-15 LPM Barb Outlet Model 18302GMN. 5.0 out of 5 stars 12 product ratings. 5.0 average based on 12 product ratings. 5. 12 users rated this 5 out of 5 stars 12. 4. 0 users rated this 4 out of 5 stars 0. 3. 0 users rated this 3 out of 5 …

Oxygen Demand Valves & Kits - O-Two

Designed to operate on any 50 psi oxygen source, the Demand Valve Resuscitator comes complete with supply hose with DISS fittings, and Universal Resuscitation Mask. Features. Provides fast, effective method to ventilate the non-breathing patient. Allows both hands to remain on the mask when depressing the Manual Ventilation Button. Durable anodized aluminum body. Provides 40 L/min Manual Flow

Oxygen Manifold System - For Mass Casualty | Penn Care, Inc.

27/6/2021· • Lead hose with optional inlet connections and lengths between flowmeters, DISS, Ohio, Chemetron • Connectible to any 50-psi oxygen gas source • Lanyards for suspending Flowmeters from IV Poles, or railing systems. Product Details In the event of a disaster or mass casualty incident, it is important to have all the equipment necessary at a moment''s notice to provide proper care. The

Oxygen Nasal Cannula | Ultra Soft | High Flow

The 16SOFT come in two hose lengths, 4 foot or 7 foot. These are Ideal for all oxygen sources with flows up to 6 LPM, such as oxygen concentrator, pulse dose conservers, portable concentrators or cylinders. Also available: The Salter Labs 16SOFT-HF Series " HIGH FLOW "for users needing 6 to 15 LPM, same great comfort. Comes in 7 foot only.

Welding Hose Reel, Welding, Hose Grade R, 200 psi, Hose

Welding Hose Reel, Welding, Hose Grade R, 200 psi, Hose Capacity 50 ft (1/4 in ID) Item # 38EE87; Mfr . Model # TW7450 OLP (oxygen and acetylene gas) or Grade T (oxygen and fuels) hoses. Welding spring-return reels are used with oxygen and acetylene welding hoses in service bays, fabriion shops, and on welding carts. View More. Compare this product Web Price Please sign in to …

NEW 300PSI 50ft 1/4 Twin Welding Torch Hose Oxy Acetylene

ABN Oxygen Acetylene Hose 1/4 Inch B Fittings Twin Welding Hose Oxy Acetylene Torch Hose Cutting Torch Hoses, 25 Foot . Valley Oxy/acet,hose, Grade R, Twin Welding 1/4-inch By 50-feet. Add to Cart Add to Cart Add to Cart Add to Cart Add to Cart Add to Cart Customer Rating: 4.0 out of 5 stars: 4.2 out of 5 stars: 4.7 out of 5 stars: 4.3 out of 5 stars: 4.4 out of 5 stars: 4.4 out of 5 stars

Technical Service Manual - Maxtec

• 50 psi supply source of medical grade oxygen • TSI 4000 series flow meter – Model 4040 E – see with inlet filter (Filter 22mm ISO Taper) • PC – used to fix settings of the TSI 4000 series flow meter. • 22mm dia. corrugated tubing – 22” length. • Flow Inspection Tool – Maxtec Part #: MT130 (0-60 LPM MaxVenturi) • Flow Inspection Tool – Maxtec Part

Oxygen Hose | McMaster-Carr

Reels come with two abrasion, weather, and ozone resistant hoses. Both lines lock in place when pulled out of the reel; they retract with a quick tug.. Grade R Hose — Green hose is for oxygen and has right-hand threads on the fittings; red hose is for acetylene and has left-hand threads on the fittings.. Grade T Hose — It''s also oil and flame resistant. Green hose is for oxygen and has

OXYGEN SERVICING 1. General Maintenance Precautions NOTE

A. Maximum pressure for the oxygen cylinder is I= PSI at 70''F. NOTE: For the minimum supply required for the crew, refer. to the Gulfstream II Airplane Flight Manual, Limitations Section. B. Replace oxygen cylinder if pressure b less than 50 psi. C. Recharge cylinder through filler valve loed on left side of nose wheel well. (Aircraft not